Temperature range: 500 ~ 1000 C, digital display adjustable,
Temperature error: 10 C (500 ~ 750 C); 15 C (750 ~ 1000 C), temperature measuring instruments Accuracy 0.5 magnitude.
Temperature sensors: 0.5K type armored thermocouple, thermocouple imports.
Pressure applied to the specimen: 0.8N ~ 1.2N, and limit the indentation depth of at least 7mm.
Timing range: 0 to 99 minutes 99 seconds adjustable,
And having Shi burning time (Ta, generally according to standards set to 30), second holding burning time (Ti) and the flame goes out time (Te) of the timer;
Time error: 1s.
Ignited bedding layer: 10mm thick white pine wood, covered 12g / m2 ~ 30g / m2 standard tissue paper, from under the glow wire 200mm 5mm
The operation is simple, stable and reliable temperature measurement system, and automatic temperature compensation.