Australia, South America, Central America, North America, Asia
All India
Product Description
Introduction: This machine is designed according to ISO12127-2007 and EN702 design and development and manufacturing; The instrument use the heating cylinder to provide a constant temperature in contact with the sample under certain load and a calorimeter to measure the heat transfer properties; the instrument is easy to operate, the data is accurate, safe and reliable, widely used in fire protective clothing related companies and inspection departments; Model : FTech-ISO12127 Standard: ISO12127-2007 EN702 Technical Parameters 1. The device is consists of a control box and stainless steel test gantry; 2. The sample holder is automatic lifting, the lifting speed is 5mm ± 0.2mm / s 3.The K type sheathed thermocouples, diameter 2mm, temperature measurement accuracy of 0.1 ºC; 4. The heating barrel temperature is greater than 500 ºC; the contact surface of the sample diameter 25.2 ± 0.05mm 5. The barrel heating load weight 49N, can be adjusted; 6. Timer scope 99999s; timing accuracy 0.1s; 7. Calorimeter fixed disk diameter 25mm, thickness 5mm; and assembly platinum resistance temperature sensor; 8. Support frame material is nylon 66; diameter 40mm height 50mm; 9. Specimen diameter 80mm; 10. PLC and touch screen for intelligent control system; 11. PID intelligent temperature control, the system automatically collect temperature data; 12. The system automatically calculates test data, automatic storage; can print freely; 13. The test table size: 650mm x 350 mm x 650mm; 14. Power supply 220V 50 / 60Hz, power 800w.